Telecom Relay HLS6-4100H


Packaging: 100pcs/tray, weight: 350g/tray

Net weight: 3.3g/pc


CONTACT DATA :

Contact Form1A/1C
Contact MaterialAu+Ag Alloy
Contact Ratings3A:120VAC/24VDC
Max Switching Voltage240VAC/60VDC
Max Switching Current3A
Max Switching Power240VA/90W
Initial Contact Resistance50m Ω Max at 6VDC 1A
Life Expectancy Electrical100,000 Operations(rated load)
Life Expectancy Mechanical10,000,000 Operations(no load)

GENERAL DATA:

Insulation Resistance100M Ω Min at500VDC
Dielectric Strength Between Open Contacts500VAC 50-60HZ( 1 minute)
Dielectric Strength Between Contacts And Coil1000VAC 50-60HZ( 1 minute)
Operate Time5ms max
Release Time5ms max
Ambient Temperature-25 ℃ to+70 ℃
Shock ResistanceMalfunction10G
Destruction10G
Vibration Resistance10-55Hz,1.5mm double amplitude
Ambient humidity40-85% RH
WeightApprox 4g
Safety StandardUL CQC

COIL DATA : (@20 ℃ )

Rated Voltage (VDC)
Coil Resistance Ω ( ± 10% )
Max Operate Voltage (VDC)
Min Release Voltage (VDC)
Max Applied Voltage (VDC)
0.2W
0.36W
3
45
25
2.25
0.15
3.9
5
125
70
3.75
0.25
6.5
6
180
100
4.5
0.3
7.8
9
405
225
6.75
0.45
11.7
12
720
400
9
0.6
15.6
24
2800
1600
18
1.2
31.2


PC Board Layout & Wiring Diagram (Bottom View) unit: mm

HLS6-4100H-Drawing.jpg




RLY-PM-005

100

3.20

100pcs/lot